In our daily lives, bagged goods are everywhere, and supermarkets are abundant with countless items. All of these products can be attributed to the automation of packaging machinery.
The method for handling the temperature failure of automated packaging machinery is as follows: When the temperature of automated packaging machinery cannot rise, it is easy to judge, but it is still quite complicated for ordinary operators. First, they need to check whether the fuse is damaged and whether the relay is damaged. Use a multimeter to measure it. If there is no multimeter, use a test pen. If there is no damage, the next step is to check whether the wiring of the heating rod is loose. If not, take off the wire of the heating rod and test the resistance. If the resistance is infinite, then the heating rod will be over If you don't have a multimeter, just try changing one by one. Another issue is that the thermocouple is damaged, which is easy to diagnose. Either the temperature control meter displays a "1" on the far left, or the temperature keeps fluctuating greatly. Simply replacing the thermocouple can solve the problem.